Neva

Designed for first-pass success with all types of clots. Uniquely designed with Drop Zone technology to capture clot inside the device.

Greater success on the first pass.

The NeVa mechanical thrombectomy system is temporarily inserted into the cerebral or coronary vascular system under angiographic visualization to restore blood flow and remove thrombus in arteries or vessels blocked by thromboembolic material. The system is available in various sizes and configurations.

STUDY A

STUDY B

Superior first pass success

STUDY A

Successful first pass recanalization: percentage of eTICI 2B-3 in the CLEAR study (mITT, n = 107)

STUDY B

Excellent first pass recanalization: percentage of eTICI 2C-3 in the CLEAR study (mITT, n = 107)

* Core-lab adjudicated results from FDA-regulated IDE study NeVa CLEAR presented by Yoo A, et al. abstract 4311, ISC, Feb. 2023

Highly efficacy design agnostic to clot morphology*

* Results from in-vitro simulated thrombectomy studies: Machi P, et al. Journal of Neuroradiology. April 2018. Results from animal model study: Ulm A.J. et al. Interventional Neurology 2018 ; 7 :205-2017

STUDY A

Successful in removing all clot types.

Neva recanalization rates in different clot morphologies.

Results from animal model study: Ulm A.J. et al. Interventional Neurology 2018 ; 7 :205-2017

STUDY B

Successful where other devices fail.

Success rate of stent retrievers when interaction with large white thrombi (≥6 mm)

Results from in-vitro simulated thrombectomy studies: Machi P, et al. JNIS. 2016; 0:1–7 and Machi P, et al. Journal of Neuroradiology. April 2018

STUDY A

STUDY B

ALL TESTED DEVICES FAILED:

Solitaire – Trevo – Embotrap – Preset – Preset LT – Catch –
Eric – Separator 3D

0%

NEVA SUCCEEDED:

60%

STUDY A

STUDY B

Proven safety*

* Results from FDA-regulated IDE study NeVa CLEAR presented by Yoo A, et al. abstract 4311, ISC, Feb. 2023.

STUDY A

Composite endpoint of 90-day all-cause mortality and/or 24-hour post-procedure sICH (ITT, n = 139)

STUDY B

Superior clinical outcomes (mRS ≤ 2 at 90 days) in the CLEAR study versus with predicate studies (mITT, n = 107).

Maximized retention, Maximized reperfusion

Significantly better at preventing clot fragments from embolizing distal territories*

Results from randomized, in-vitro simulated thrombectomy studies: Vania et al. JVIN, Feb 2023, Li et al. JNIS, May 2023

Clot fragments generated*

Results from randomized, in-vitro simulated thrombectomy studies: Vania et al. JVIN, Feb 2023

Frequency of large emboli generated.*

Results from randomized, in-vitro simulated thrombectomy studies: Li et al. JNIS, May 2023

28% LESS

FRAGMENTS > 1mm generated versus Solitaire

P=0.003

24% LESS

FRAGMENTS >1mm generated versus Embotrap 2

P=0.003

Total area of emboli generated.*

Results from randomized, in-vitro simulated thrombectomy studies: Li et al. JNIS, May 2023

The structure in detail

Product Number

30020V-MS

VN-4529-03RR

VN-5537-03RR

VN-5537-03NR

Description

NeVa 4.0 x 22 mm

NeVa 4.5 x 29 mm

NeVa 5.5 x 37 mm

NeVa NET 5.5 x 37 mm

Diameter (mm)

4.0

4.5

5.5

5.5

Working Lemgth (mm)

22

29

37

37

Total Basket Length (mm)

39

46

56

56

Push-wire Length (mm)

180

180

180

180

Number of Drop Zones

2

3

3

3

Minimum MC ID (Inches)

.021″

.021″

.027″

.027″