The first and only integratedmicrofiltrationtechnology. NeVa Net devices incorporate a unique braided mesh within the distal end of the expandable tip.
The next frontier in thrombectomy.
The first and only integrated microfiltration technology designed to maximize clot retention.
STUDY A
STUDY B
Superior first pass success*
STUDY A
Successful first pass recanalization: percentage of eTICI 2B-3 in the CLEAR study (mITT, n = 107)
STUDY B
Excellent first pass recanalization: percentage of eTICI 2C-3 in the CLEAR study (mITT, n = 107)
* Core-lab adjudicated results from FDA-regulated IDE study NeVa CLEAR presented by Yoo A, et al. abstract 4311, ISC, Feb. 2023
Highly efficacy design agnostic to clot morphology*
* Results from in-vitro simulated thrombectomy studies: Machi P, et al. Journal of Neuroradiology. April 2018. Results from animal model study: Ulm A.J. et al. Interventional Neurology 2018 ; 7 :205-2017
STUDY A
SUCCESSFUL IN REMOVING ALL CLOT TYPES.
Neva recanalization rates in different clot morphologies.
Results from animal model study: Ulm A.J. et al. Interventional Neurology 2018; 7 :205-2017
STUDY B
SUCCESSFUL WHERE OTHER DEVICES FAIL.
Success rate of stent retrievers when interaction with large white thrombi (≥6 mm).
Results from in-vitro simulated thrombectomy studies: Machi P, et al. JNIS. 2016; 0:1–7 and Machi P, et al. Journal of Neuroradiology. April 2018
STUDY A
STUDY B
ALL TESTED DEVICES FAILED:
Solitaire – Trevo – Embotrap – Preset – Preset LT – Catch – Eric – Separator 3D
0%
NEVA SUCCEEDED:
60%
STUDY A
STUDY B
Proven safety*
* Results from FDA-regulated IDE study NeVa CLEAR presented by Yoo A, et al. abstract 4311, ISC, Feb. 2023.
STUDY A
Composite endpoint of 90-day all-cause mortality and/or 24-hour post-procedure sICH (ITT, n = 139).
STUDY B
Superior clinical outcomes (mRS ≤ 2 at 90 days) in the CLEAR study versus with predicate studies (mITT, n = 107).
Maximized retention, Maximized reperfusion
SIGNIFICANTLY BETTER AT PREVENTING CLOT FRAGMENTS FROM EMBOLIZING DISTAL TERRITORIES*
*Results from randomized, in-vitro simulated thrombectomy studies: Vania et al. JVIN, Feb 2023, Li et al. JNIS, May 2023.
CLOT FRAGMENTS GENERATED*
*Results from randomized, in-vitro simulated thrombectomy studies: Vania et al. JVIN, Feb 2023.
FREQUENCY OF LARGE EMBOLI GENERATED*
*Results from randomized, in-vitro simulated thrombectomy studies: Li et al. JNIS, May 2023.
28% LESS
FRAGMENTS > 1mm generated versus Solitaire
P=0.003
24% LESS
FRAGMENTS > 1mm generated versus Embotrap 2.
P=0.003
TOTAL AREA OF EMBOLI GENERATED*
*Results from randomized, in-vitro simulated thrombectomy studies: 6. Li et al. JNIS, May 2023.