Neva Net

The first and only integrated microfiltration technology. NeVa Net devices incorporate a unique braided mesh within the distal end of the expandable tip.

The next frontier in thrombectomy.

The first and only integrated microfiltration technology designed to maximize clot retention.

STUDY A

STUDY B

Superior first pass success*

STUDY A

Successful first pass recanalization: percentage of eTICI 2B-3 in the CLEAR study (mITT, n = 107)

STUDY B

Excellent first pass recanalization: percentage of eTICI 2C-3 in the CLEAR study (mITT, n = 107)

* Core-lab adjudicated results from FDA-regulated IDE study NeVa CLEAR presented by Yoo A, et al. abstract 4311, ISC, Feb. 2023

Highly efficacy design agnostic to clot morphology*

* Results from in-vitro simulated thrombectomy studies: Machi P, et al. Journal of Neuroradiology. April 2018. Results from animal model study: Ulm A.J. et al. Interventional Neurology 2018 ; 7 :205-2017

STUDY A

SUCCESSFUL IN REMOVING ALL CLOT TYPES.

Neva recanalization rates in different clot morphologies.

Results from animal model study: Ulm A.J. et al. Interventional Neurology 2018; 7 :205-2017

STUDY B

SUCCESSFUL WHERE OTHER DEVICES FAIL.

Success rate of stent retrievers when interaction with large white thrombi (≥6 mm).

Results from in-vitro simulated thrombectomy studies: Machi P, et al. JNIS. 2016; 0:1–7 and Machi P, et al. Journal of Neuroradiology. April 2018

STUDY A

STUDY B

ALL TESTED DEVICES FAILED:

Solitaire – Trevo – Embotrap – Preset – Preset LT – Catch – Eric – Separator 3D

0%

NEVA SUCCEEDED:

60%

STUDY A

STUDY B

Proven safety*

* Results from FDA-regulated IDE study NeVa CLEAR presented by Yoo A, et al. abstract 4311, ISC, Feb. 2023.

STUDY A

Composite endpoint of 90-day all-cause mortality and/or 24-hour post-procedure sICH (ITT, n = 139).

STUDY B

Superior clinical outcomes (mRS ≤ 2 at 90 days) in the CLEAR study versus with predicate studies (mITT, n = 107).

Maximized retention, Maximized reperfusion

SIGNIFICANTLY BETTER AT PREVENTING CLOT FRAGMENTS FROM EMBOLIZING DISTAL TERRITORIES*

*Results from randomized, in-vitro simulated thrombectomy studies: Vania et al. JVIN, Feb 2023, Li et al. JNIS, May 2023.

CLOT FRAGMENTS GENERATED*

*Results from randomized, in-vitro simulated thrombectomy studies: Vania et al. JVIN, Feb 2023.

FREQUENCY OF LARGE EMBOLI GENERATED*

*Results from randomized, in-vitro simulated thrombectomy studies: Li et al. JNIS, May 2023.

28% LESS

FRAGMENTS > 1mm generated versus Solitaire

P=0.003

24% LESS

FRAGMENTS > 1mm generated versus Embotrap 2.

P=0.003

TOTAL AREA OF EMBOLI GENERATED*

*Results from randomized, in-vitro simulated thrombectomy studies: 6. Li et al. JNIS, May 2023.

The structure in detail

Product Number

30020V-MS

VN-4529-03RR

VN-5537-03RR

VN-5537-03NR

Description

NeVa 4.0 x 22 mm

NeVa 4.5 x 29 mm

NeVa 5.5 x 37 mm

NeVa NET 5.5 x 37 mm

Diameter (mm)

4.0

4.5

5.5

5.5

Working Lemgth (mm)

22

29

37

37

Total Basket Length (mm)

39

46

56

56

Push-wire Length (mm)

180

180

180

180

Number of Drop Zones

2

3

3

3

Minimum MC ID (Inches)

.021″

.021″

.027″

.027″